Bloom LabsFree shipping from $250 CADBuilt to a higher standard.Payments opening soonThoughtfully packagedShipped across CanadaLab reports on requestCanada-onlyBloom LabsFree shipping from $250 CADBuilt to a higher standard.Payments opening soonThoughtfully packagedShipped across CanadaLab reports on requestCanada-onlyBloom LabsFree shipping from $250 CADBuilt to a higher standard.Payments opening soonThoughtfully packagedShipped across CanadaLab reports on requestCanada-onlyBloom LabsFree shipping from $250 CADBuilt to a higher standard.Payments opening soonThoughtfully packagedShipped across CanadaLab reports on requestCanada-onlyBloom LabsFree shipping from $250 CADBuilt to a higher standard.Payments opening soonThoughtfully packagedShipped across CanadaLab reports on requestCanada-onlyBloom LabsFree shipping from $250 CADBuilt to a higher standard.Payments opening soonThoughtfully packagedShipped across CanadaLab reports on requestCanada-onlyBloom LabsFree shipping from $250 CADBuilt to a higher standard.Payments opening soonThoughtfully packagedShipped across CanadaLab reports on requestCanada-onlyBloom LabsFree shipping from $250 CADBuilt to a higher standard.Payments opening soonThoughtfully packagedShipped across CanadaLab reports on requestCanada-only
Journal

Documentation

Reading a peptide COA: identity, purity and batch matching

By Bloom Labs · Published · 1 min read

Read a peptide COA as a set of separate, method-specific results. First match the report to the material; then distinguish identity, chromatographic purity and content rather than treating one percentage as a complete quality verdict.

Match the document before reading the number

Compare the product name and lot or batch identifier on the report and on the vial. Review the sample description, report date and laboratory. Missing or conflicting identifiers weaken the connection between the report and the material in hand.

Separate the analytical questions

IdentityMass spectrometry may compare an observed mass with the expected mass.
HPLC purityA peak-area percentage under the stated chromatographic method; it is not the same as total peptide content.
ContentThe peptide mass fraction can differ from an HPLC area result because water, salts and counter-ions may contribute to sample mass.
Sterility and endotoxinSeparate questions requiring their own methods; neither follows from an HPLC purity result.

Ask what the report actually supports

Check whether the method, result, units and acceptance criteria are visible. Do not infer fill quantity, sterility, biological activity or suitability from an identity or purity line. Technical suppliers and pharmacopeial resources describe these as distinct quality attributes. [GenScript peptide purity guidance][USP peptide quality resources]

Check presentation and context

A graph without a readable sample identifier or method conditions offers limited context. Note whether chromatograms and spectra are attached, whether axes and peaks are legible, and whether the stated conclusion clearly corresponds to those pages. This is a document-consistency check, not an independent validation of the laboratory work.

References

Each reference describes a particular study or document. It does not verify any Bloom Labs lot, and it does not indicate that a product is authorized for sale in Canada.

  1. MilliporeSigma technical article explaining how reported peptide amount relates to net peptide content. View source: MilliporeSigma peptide amount explanation (opens in a new tab)
  2. GenScript technical resource describing peptide purity reporting. View source: GenScript peptide purity guidance (opens in a new tab)
  3. United States Pharmacopeia resource on synthetic peptide quality attributes. View source: USP peptide quality resources (opens in a new tab)